Should use Integer not String for checkout timeout value

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Closed (View Workflow)
    • Priority: P1
    • Resolution: Done
    • Affects Version/s: None
    • Fix Version/s: 2.0.0
    • Labels:
    • Template:
    • Sprint:
      EPAM-Veg Sprint 36
    • Story Points:
      0.5
    • Development Team:
      Vega

      Description

      Found following issue when troubleshooting Chalmers error.
      Go to circulation setting page on any q4 or q1 sites: for example https://folio-testing.aws.indexdata.com/settings/circulation/checkout
      Fill some value and click save. Check network traffic and notice "3" not 3 is used for checkTimeoutDuration. That causes backend failures when timer kicks off.

       
      {"audioAlertsEnabled":false,"prefPatronIdentifier":"BARCODE","checkoutTimeout":true,"checkoutTimeoutDuration":"3"}"
      