Details
-
Story
-
Status: Closed (View Workflow)
-
P3
-
Resolution: Done
-
None
-
-
Folijet Sprint 123
-
3
-
Folijet
-
R3 2021
Description
Mapping for new Instance identifier type: Cancelled system control number
See row 20 in the FOLIJET Instance from MARC tab of the mappings worksheet: https://docs.google.com/spreadsheets/d/11lGBiPoetHuC3u-onVVLN4Mj5KtVHqJaQe4RqCxgGzo/edit#gid=1871391984
Plus the examples in the attached MARC file
- Scenario 1
- For data in MARC Field 019, Subfield a,
- Map to the Instance Identifier field, with Identifier type = Cancelled system control number
- NOTE: If multiple $a in the same 019 field, put each one into a separate Instance identifier field
- Scenario 2
- For data in MARC Field 035, Subfield z,
- Map to the Instance Identifier field, with Identifier type = Cancelled system control number
- NOTES:
- If multiple $z in the same 035 field, put each one into a separate Instance identifier field
- If the $z has prefix (OCoLC), ocm, or ocn, assign Identifier type = Cancelled system control number, NOT OCLC
abreaux Once this is live, confirm that the option for Cancelled system control number shows in the options for Instance matches
TestRail: Results
Attachments
Issue Links
- defines
-
UXPROD-2924 Recently UNblocked Mapping updates for Inventory records
-
- Closed
-
- has to be done after
-
MODINVSTOR-636 Resource identifier type - add new value: Cancelled system control number
-
- Closed
-
- relates to
-
UXPROD-2152 Additional MARC-Instance relationship refinement - DRAFT
-
- Draft
-